What points should be paid attention to when understanding the wiring of the cabinet
column:application cases Release time:2022-10-06

In the entire data center wiring project, the weak current cabinet wiring is a very delicate work. Messy wiring not only increases the difficulty of management, but also affects network quality. The following is a brief sharing of the points to pay attention to when understanding the wiring of the cabinet, and the method of making the wiring of the cabinet orderly when doing the internal wiring of the cabinet.

 

the wiring of the cabinet

the wiring of the cabinet

 

What points should be paid attention to when understanding cabinet wiring?

 

  1. Make sure that the cooling fan or air-conditioning vent of the cabinet is open to avoid overheating of the equipment and causing a crash. The switch should be fixed on the top of the cabinet with matching ears to facilitate the positioning of the network cable.

 

  1. Each network cable inside the cabinet should have a label to avoid unnecessary trouble for later maintenance. Cable labels need to be pasted at the bends of the cables to maintain a relevant height, and the orientation should be neat. When tying the cables on the back of the cabinet, it is necessary to bundle the optical fibers, network cables, and power cables in order from the inside to the outside, and keep the cables horizontally and vertically.

 

  1. Stick the asset number on each server, and print out the asset number + barcode together through the label printer. Each server prints two identical sheets, and pastes one on the front and one side of the device. The cable tie labels with the same number must be marked on the rear end of the network cable connecting the server and the switch at both ends, and the number should be consistent with the port number of the switch.

 

  1. Generally, the power cable and the network cable are routed from different directions, and each section is tied with cable ties. When wiring the cabinet, ensure that both ends of the power cord plug and server power connector are fixed with label ties. The wiring between cabinets is generally routed from the top of the cabinet. If the cabinet is a switch with internal and external networks, try to use two network cables of different colors to distinguish them.

 

The above are some points to pay attention to when wiring the cabinet. The computer room is the most important part of the network, so everyone should pay attention to this link. If you have purchase needs for weak current products, please contact sales@hj-net.com. Accept OEM/ODM