Data Center Busway

Product Overview

The smart green mini busway adopts a bus-architecture design, using busway architecture to replace traditional cabling all the way from the UPS output distribution cabinet to the PDU. The main and mini busways complete the entire end-point power distribution connection through connecting copper bars, feed-in boxes, and tap-off boxes. All plug-in power distribution units adopt a plug-and-play design, greatly facilitating installation and use, and allowing power distribution units to be connected or disconnected without interrupting power to the busway, providing uninterrupted continuous power access. The system is maintenance-free, and the power distribution units can be reused, significantly saving operation and maintenance costs.

Architecture:
Bus architecture, full busway connection from UPS to PDU
Connection components:
Connecting copper bars, feed-in box, tap-off box
Maintenance method:
Maintenance-free, power distribution units are reusable
Installation feature:
Plug-and-play; can be connected or disconnected without interrupting power to the busway

Key Advantages

Bus architecture design

End-to-end busway architecture from UPS to PDU, replacing traditional cabling and reducing wiring complexity and points of failure

Online hot-swapping

Power distribution units can be connected or disconnected without interrupting power to the busway, ensuring business continuity

Maintenance-free and reusable

Power distribution units are maintenance-free and reusable, greatly reducing operation and maintenance costs

High-density adaptability

The plug-and-play design matches high-density power distribution needs in data centers, with flexible installation and easy expansion

Data Center Busway

Application Scenarios

Data Center

Data Center

Ensure stable operation of cabinets, power distribution, cabling and key equipment

Communication Base Station

Communication Base Station

Supports installation, power supply, wiring and protection for base station equipment

Carrier Transmission Node

Carrier Transmission Node

For fiber access, convergence distribution and line management

Enterprise Computer Rooms & Edge Nodes

Enterprise Computer Rooms & Edge Nodes

Supports centralized deployment of small computer rooms and edge computing nodes

Related Products

View All Products
Ac Header Cabinet

Ac Header Cabinet

AC row head cabinet for equipment rooms, using current transformers to collect three-phase power data, supporting multi-level alarm storage, and interfacing with equipment room DCIM/environmental monitoring systems via the Modbus protocol.

Rated Operating Voltage:380V three-phase AC

IP Rating:≥IP30

Operating Temperature:-5℃~55℃

Dimensions:600-1200 300-1200 2000-2600mm

Ac Power Distribution

Ac Power Distribution

Three-phase AC power distribution cabinet, powered by mains electricity, featuring triple protection against short circuit, overcurrent, and overvoltage, with remote status indication support, suitable for buildings and factory scenarios.

Power supply method:Three-phase, three-wire

Operating voltage:±10% (rated)

Operating frequency:50HZ

Protection functions:Short circuit/overcurrent/overvoltage

Pv Distribution Box

Pv Distribution Box

PV AC grid-connected power distribution cabinet with integrated lightning protection, anti-islanding protection, and a visible isolation switch disconnect point, suitable for PV grid-connected power generation scenarios.

Lightning protection:Input surge arrester

Metering method:Sealed energy meter

Monitoring interface:RS485 (optional)

Safety configuration:Visible isolation switch disconnect point

Pv Combiner Box

Pv Combiner Box

PV lightning-protection DC combiner box with integrated fuses, surge arresters, and parameter acquisition, covering a voltage range of 100VDC to 1000VDC, suitable for PV power station scenarios.

Voltage range:100VDC~1000VDC

Current range:10A~160A

Enclosure finish:Electrostatic spray coating

Sealed design:Fully sealed cable entry holes

ATS Transfer Switchgear

ATS Transfer Switchgear

Dual-power automatic transfer switch cabinet with a flame-retardant degreased fiber insulated switch body, supporting automatic switching between main and backup power, suitable for emergency power supply scenarios.

Product Dimensions:(400-1200)×(600-1200)×2200mm

Operating Temperature:-5℃~55℃

Insulation material:Flame-retardant degreased fiber

Applicable standard:GB/T2820

UPS Power Distribution

UPS Power Distribution

Standardized prefabricated UPS power distribution cabinet supporting hot-swappable miniature circuit breakers and three-phase load balancing adjustment, suitable for data center power distribution scenarios.

Product Dimensions:(400-1200)×(350-800)×(400-2200)mm

Operating Temperature:-5℃~55℃

Input type:Dual-power switching

Safety design:Front and rear panel isolation

Battery Thermostat Box

Battery Thermostat Box

Six-sided insulated phase-change energy storage thermostatic box with a heat transfer coefficient of no more than 0.3W/(m²·K), supporting passive temperature control and remote monitoring, suitable for base station battery scenarios.

Heat transfer coefficient:≤0.3W/(㎡·K)

IP Rating:IP45

Temperature rise control:≤5°C within 6h (no heat source)

Energy saving rate:Up to 40% for equipment room air conditioning

Low Voltage Switchgear

Low Voltage Switchgear

Modular low-voltage switchgear cabinet supporting mixed installation of withdrawable and fixed units, integrating power distribution and motor control functions, suitable for industrial power distribution scenarios.

Product Dimensions:(400-1200)×(600-1200)×2200mm

Operating Temperature:-5℃~55℃

Circuit configuration:S-type 36 circuits/U-type 48 circuits

Segregation class:Form 4b (GB7251.12-2013)

Reliable protection for critical infrastructure

Contact Engineering Team