Dc Power Distribution

Product Overview

The DC power distribution cabinet is used in hydroelectric and thermal power plants as well as various substations. It consists of a battery bank, charging device, DC feeder panel, DC power monitoring device, and DC branch feeders, forming a DC power supply network throughout the station. Each monitoring unit is uniformly managed by the master monitor via RS485 communication lines. The master monitor displays various information, and users can query it via touch or keypad to achieve four remote functions, with system information accessible to remote monitoring. Optional functional units such as insulation monitoring, battery inspection, and switch status monitoring can also be configured. Operating temperature ranges from -5°C to 55°C, with relative humidity not exceeding 80%.

Product Dimensions:
Customizable
Operating Temperature:
-5℃~55℃
Communication method:
RS485
Monitoring function:
Insulation monitoring/battery inspection

Key Advantages

High Protection Rating

IP68-rated waterproof, dustproof, and corrosion-resistant for harsh outdoor environments.

Wide-Temperature Operation

Stable performance from -40°C to 60°C for deployment in extreme cold and heat.

Robust Structure

High-strength stainless steel with reinforced design for long-term equipment safety.

Flexible Configuration

Multiple sizes and interface options to meet diverse project requirements.

Dc Power Distribution

Application Scenarios

Communication Base Station

Communication Base Station

Supports installation, power supply, wiring and protection for base station equipment

Data Center

Data Center

Ensure stable operation of cabinets, power distribution, cabling and key equipment

New Energy Power Supporting Equipment

New Energy Power Supporting Equipment

Applicable to communication, power distribution and protection for energy applications

Low-Voltage Systems for Campus and Buildings

Low-Voltage Systems for Campus and Buildings

Supports access and management for park and building low-voltage systems

Technical Specifications

Operating Environment Specifications
Operating Temperature -5℃~55℃
Storage temperature -20℃~+55℃
Operating Relative Humidity Not exceeding 80% (at +30°C)
Storage relative humidity ≤90%~96%(40℃±2℃)
Atmospheric pressure 65~110kpa
Product Dimensions Customizable per customer requirements

Note: Specifications shown are standard values. Actual performance may vary depending on installation environment, component compatibility, and grid conditions. We reserve the right to continuously optimize design and specifications. For final technical proposals and formal quotations, please contact our sales team to request an official specification confirmation document.

Related Products

View All Products
Pv Distribution Box

Pv Distribution Box

PV AC grid-connected power distribution cabinet with integrated lightning protection, anti-islanding protection, and a visible isolation switch disconnect point, suitable for PV grid-connected power generation scenarios.

Lightning protection:Input surge arrester

Metering method:Sealed energy meter

Monitoring interface:RS485 (optional)

Safety configuration:Visible isolation switch disconnect point

ATS Transfer Switchgear

ATS Transfer Switchgear

Dual-power automatic transfer switch cabinet with a flame-retardant degreased fiber insulated switch body, supporting automatic switching between main and backup power, suitable for emergency power supply scenarios.

Product Dimensions:(400-1200)×(600-1200)×2200mm

Operating Temperature:-5℃~55℃

Insulation material:Flame-retardant degreased fiber

Applicable standard:GB/T2820

Pv Combiner Box

Pv Combiner Box

PV lightning-protection DC combiner box with integrated fuses, surge arresters, and parameter acquisition, covering a voltage range of 100VDC to 1000VDC, suitable for PV power station scenarios.

Voltage range:100VDC~1000VDC

Current range:10A~160A

Enclosure finish:Electrostatic spray coating

Sealed design:Fully sealed cable entry holes

UPS Power Distribution

UPS Power Distribution

Standardized prefabricated UPS power distribution cabinet supporting hot-swappable miniature circuit breakers and three-phase load balancing adjustment, suitable for data center power distribution scenarios.

Product Dimensions:(400-1200)×(350-800)×(400-2200)mm

Operating Temperature:-5℃~55℃

Input type:Dual-power switching

Safety design:Front and rear panel isolation

Ac Power Distribution

Ac Power Distribution

Three-phase AC power distribution cabinet, powered by mains electricity, featuring triple protection against short circuit, overcurrent, and overvoltage, with remote status indication support, suitable for buildings and factory scenarios.

Power supply method:Three-phase, three-wire

Operating voltage:±10% (rated)

Operating frequency:50HZ

Protection functions:Short circuit/overcurrent/overvoltage

Battery Thermostat Box

Battery Thermostat Box

Six-sided insulated phase-change energy storage thermostatic box with a heat transfer coefficient of no more than 0.3W/(m²·K), supporting passive temperature control and remote monitoring, suitable for base station battery scenarios.

Heat transfer coefficient:≤0.3W/(㎡·K)

IP Rating:IP45

Temperature rise control:≤5°C within 6h (no heat source)

Energy saving rate:Up to 40% for equipment room air conditioning

Outdoor Power Cabinet

Outdoor Power Cabinet

Outdoor integrated power cabinet with integrated batteries, rectifiers, and AC/DC power distribution, equipped with a 200A rectifier power supply, suitable for communication base station scenarios.

Product Dimensions:2000×700×700mm

IP Rating:IP55 (outdoor air-conditioned type)

Static load capacity:≥1200kg (floor-standing)

Panel material:2.0mm aluminum-zinc coated sheet (uprights)

Lightning Protection Box

Lightning Protection Box

Lightning protection box supporting power indication, lightning protection failure indication, and automatic lightning strike counting, with a dual-power supply structure, suitable for communications, electric power, and transportation scenarios.

Operating Temperature:-5℃~55℃

Enclosure protection:Waterproof, fireproof, and moisture-proof

Power supply structure:Dual power supply

Alarm function:Degradation alarm/lightning strike counting

Reliable protection for critical infrastructure

Contact Engineering Team