Dc Header Cabinet

Product Overview

The DC end-of-row cabinet is used in hydroelectric and thermal power plants as well as various substations. It consists of a battery bank, charging device, DC feeder panel, DC power distribution cabinet, DC power monitoring device, and DC branch feeders, forming a DC power supply network throughout the station. It provides a safe and reliable working power supply for subsystems such as relay protection devices, circuit breaker tripping/closing, signal systems, DC chargers, UPS, and communications. The system supports RS485 communication networking and four remote functions. Operating temperature ranges from -5°C to 55°C, with relative humidity not exceeding 80%.

Product Dimensions:
(400-1200)×(300-1200)×(2000-2600)mm
Operating Temperature:
-5℃~55℃
System composition:
Battery bank, charging device, DC feeder panel, monitoring device
Communication method:
RS485, supports four remote functions

Key Advantages

Modular system architecture

Composed of standardized units such as battery bank, charging device, DC feeder panel, and monitoring device, with a clear structure that is easy to expand

Unified RS485 networking

Each monitoring unit reports uniformly to the master monitor via RS485 communication lines, enabling centralized and efficient information management

Comprehensive four-remote monitoring

The master monitor supports data display, touch query, and four remote functions, and can be connected to a remote monitoring system

Customizable wide-range dimensions

Product dimensions (400-1200) x (300-1200) x (2000-2600)mm, customizable as needed

Dc Header Cabinet

Application Scenarios

Data Center

Data Center

Ensure stable operation of cabinets, power distribution, cabling and key equipment

Communication Base Station

Communication Base Station

Supports installation, power supply, wiring and protection for base station equipment

Carrier Transmission Node

Carrier Transmission Node

For fiber access, convergence distribution and line management

Enterprise Computer Rooms & Edge Nodes

Enterprise Computer Rooms & Edge Nodes

Supports centralized deployment of small computer rooms and edge computing nodes

Technical Specifications

Operating Environment Specifications
Operating Temperature -5℃~55℃
Storage temperature -20℃~+55℃
Operating Relative Humidity Not exceeding 80% (at +30°C)
Storage relative humidity ≤90%~96%(40℃±2℃)
Atmospheric pressure 65~110kpa
Product Dimensions (400-1200) W x (300-1200) D x (2000-2600) H

Note: Specifications shown are standard values. Actual performance may vary depending on installation environment, component compatibility, and grid conditions. We reserve the right to continuously optimize design and specifications. For final technical proposals and formal quotations, please contact our sales team to request an official specification confirmation document.

Related Products

View All Products
Data Center Busway

Data Center Busway

Data center smart mini busway with plug-and-play bus-architecture power distribution, supporting online insertion/removal without power interruption for maintenance, suitable for high-density data center power distribution scenarios.

Architecture:Bus architecture, full busway connection from UPS to PDU

Connection components:Connecting copper bars, feed-in box, tap-off box

Maintenance method:Maintenance-free, power distribution units are reusable

Installation feature:Plug-and-play; can be connected or disconnected without interrupting power to the busway

Ac Power Distribution

Ac Power Distribution

Three-phase AC power distribution cabinet, powered by mains electricity, featuring triple protection against short circuit, overcurrent, and overvoltage, with remote status indication support, suitable for buildings and factory scenarios.

Power supply method:Three-phase, three-wire

Operating voltage:±10% (rated)

Operating frequency:50HZ

Protection functions:Short circuit/overcurrent/overvoltage

Ac Header Cabinet

Ac Header Cabinet

AC row head cabinet for equipment rooms, using current transformers to collect three-phase power data, supporting multi-level alarm storage, and interfacing with equipment room DCIM/environmental monitoring systems via the Modbus protocol.

Rated Operating Voltage:380V three-phase AC

IP Rating:≥IP30

Operating Temperature:-5℃~55℃

Dimensions:600-1200 300-1200 2000-2600mm

Battery Thermostat Box

Battery Thermostat Box

Six-sided insulated phase-change energy storage thermostatic box with a heat transfer coefficient of no more than 0.3W/(m²·K), supporting passive temperature control and remote monitoring, suitable for base station battery scenarios.

Heat transfer coefficient:≤0.3W/(㎡·K)

IP Rating:IP45

Temperature rise control:≤5°C within 6h (no heat source)

Energy saving rate:Up to 40% for equipment room air conditioning

Low Voltage Switchgear

Low Voltage Switchgear

Modular low-voltage switchgear cabinet supporting mixed installation of withdrawable and fixed units, integrating power distribution and motor control functions, suitable for industrial power distribution scenarios.

Product Dimensions:(400-1200)×(600-1200)×2200mm

Operating Temperature:-5℃~55℃

Circuit configuration:S-type 36 circuits/U-type 48 circuits

Segregation class:Form 4b (GB7251.12-2013)

Pv Distribution Box

Pv Distribution Box

PV AC grid-connected power distribution cabinet with integrated lightning protection, anti-islanding protection, and a visible isolation switch disconnect point, suitable for PV grid-connected power generation scenarios.

Lightning protection:Input surge arrester

Metering method:Sealed energy meter

Monitoring interface:RS485 (optional)

Safety configuration:Visible isolation switch disconnect point

UPS Power Distribution

UPS Power Distribution

Standardized prefabricated UPS power distribution cabinet supporting hot-swappable miniature circuit breakers and three-phase load balancing adjustment, suitable for data center power distribution scenarios.

Product Dimensions:(400-1200)×(350-800)×(400-2200)mm

Operating Temperature:-5℃~55℃

Input type:Dual-power switching

Safety design:Front and rear panel isolation

ATS Transfer Switchgear

ATS Transfer Switchgear

Dual-power automatic transfer switch cabinet with a flame-retardant degreased fiber insulated switch body, supporting automatic switching between main and backup power, suitable for emergency power supply scenarios.

Product Dimensions:(400-1200)×(600-1200)×2200mm

Operating Temperature:-5℃~55℃

Insulation material:Flame-retardant degreased fiber

Applicable standard:GB/T2820

Reliable protection for critical infrastructure